Hot Air Oven DR 101 |
 |
|
|
![]() |
|
Hot Air Ovens are suitable for temperature up to 250 Deg C for chemicals,
glassware in laboratories, research institutions, industries, hospitals & R & D centers. This is suit to various
applications like heating, drying, sterilizing 7 baking.
|
| CONSTRUCTION: |
|
All external cases are made of mild steel, often with strong seamless welding & covered with a thick layer of
stoved epoxypolyster paint. This provide a strong, highly screech & heat resistant surface for a long lasting attractive
finish. Internal surfaces ( Including of the doors) are manufactured from either aluminium or stainless steel, with great
care in order to eliminate sharp edges. The double walled chamber is filled with high frade insulation to prevent heat
loss. Elements are of the sheathed black heat type are put inside beads & placed at the bottom & in both the side ribs are
placed for uniform temperature. The door closes on to an as bestos-gasket the shelves slide neatly into the fixed runners.
The fixed vatilators are provided on both side of the wall. The thermometer is provided on the top of oven to check the
temperature. The oven is mounted on four rubber feet to prevent slipping & this protects the bench surface. The control
panel house a main On/Off switch indicator lamp & temperature setting knob. The scale is calibrated in 5 Deg C
steps.
|
|
Sr.No.
|
Inner Chamber Size
|
No. of Tray
|
|
A.
|
300 x 300 x 300 mm
|
2 No.
|
|
B.
|
350 x 350 x 350 mm
|
2 No.
|
|
C.
|
450 x 450 x 450 mm
|
2 No.
|
|
D.
|
605 x 450 x 450 mm
|
2 No.
|
|
E.
|
605 x 605 x 605 mm
|
2 No.
|
|
F.
|
910 x 605 x 455 mm
|
2 No.
|
|
G.
|
910 x 605 x 605 mm
|
2 No.
|
|
|
OPTIONAL ACCESSORIES
- Automatic Digital Temp. controller cum Indicator
- Air
Circulating Fan
- Timer 0-24 hours
|
|
| |
|
|
|
| |
| |
|
|
 |
Incubators (Bacteriological) DR 109 |
 |
|
|
 |
|
Standard double wall fabrication. Inner
chamber made out of richly anodized aluminium or highly polished stainless steel sheet and outer made out of thick mild
steel sheet finished in white powder coating paint. Double wall door with double glass window for observation in the
chamber.
|
| Temperature range 5° C above ambient to
80° c ± 2° C controlled by a thermostat. L-shaped thermometer is provided for taking temperature readings. Panel is
provided with pilot lamps for mains & heaters, On-off switch, temperature control knob etc. The equipment is workable on
220 V AC 50 Hz single phase. Heating is achieved from 3 sides. Perforated removable shelves also provided. |
|
| Sr. |
Chamber Size in
mm |
(inches) |
No. of Shelves |
| a. |
300 x 300 x 300 |
12"x12"x12" |
2 |
| b. |
350 x 350 x 350 |
14"x14"x14" |
2 |
| c. |
400 x 400 x 400 |
16"x16"x16" |
2 |
| d. |
450 x 450 x 450 |
18"x18"x18" |
2 |
|
| Optional
Accessories for Both Ovens and Incubators |
- Air Circulating Fan
- Timer 0 - 24
Hours
- Digital Temperature Indicator
- Digital Temperature Indicator cum controller
|
|
| |
|
|
|
| |
| |
|
|
 |
B.O.D. Incubators DR 110 |
 |
|
|
 |
|
Disigned for low temperature incubation and routine
determination of Bio-chemical oxygen demand (B.O.D.) This unit is composed for triple walled chamber with a thick layer of
fine glass woof to prevent loss of heat. For lower temperature work a cooling unit is provided at the lower portion of the
working chamber and heating arrangement has been made in the inner chamber for work of higher temerature. The temperature
various from 5ºC to 50ºC adjustable at any desired point by means of a high precision double action thermo regulator with
in the variation of ± 1ºC. Air circulation fan has been provided to keep the temperature uniform inside the chamber. Inner
chamber is fabricated from thick aluminium anodized shelves are provided. Unbreakable Acrylic transparent door inside.
Referation unit is formed by ISI marked compressor.
|
| Toggle switch, temperature controller com.indicator and indicating lamps are located on the instrument for easy
handling and visibility.Complete with automatic internal light, connecting card & plug to work on 220 volts A/C. |
|
|
Sr. No.
|
Inner Chamber
Size
|
Cap. Leters
|
|
A.
|
610 x 455
x 410 mm ( 4.0 C.ft. )
|
112
|
|
B.
|
830 x 505 x
415 mm ( 6.0 C.ft. )
|
170
|
|
C.
|
875 x 570 x 550
mm ( 10 C. ft. )
|
280
|
|
D.
|
950 x 650 x 550 mm
( 12 C. ft.)
|
340
|
|
E.
|
950 x 700 x 650 mm (
15 C. ft. )
|
420
|
|
| OPTIONAL ACCESSORIES:- |
-
|
1.
|
Automatic Digital Temp. controller Indicator
|
|
2.
|
Timer for Above
|
|
3
|
Voltage Stabilizer
|
|
4.
|
Co2/Air mixer nozzle is provided
|
|
5.
|
Microprocessor PID Digital temp.
controller
|
|
|
| |
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
 |
Blood Bank Refrigerators (Vaccine Storage Cabinet) |
 |
|
|
![]() |
|
Disigned for low temperature incubation and routine determination of Bio-chemical oxygen demand (B.O.D.)
This unit is composed for triple walled chamber with a thick layer of fine glass woof to prevent loss of heat. For lower
temperature work a cooling unit is provided at the lower portion of the working chamber and heating arrangement has been
made in the inner chamber for work of higher temerature. The temperature various from 5ºC to 50ºC adjustable at any desired
point by means of a high precision double action thermo regulator with in the variation of ± 1ºC. Air circulation fan has
been provided to keep the temperature uniform inside the chamber. Inner chamber is fabricated from thick aluminium anodized
shelves are provided. Unbreakable Acrylic transparent door inside. Referation unit is formed by ISI marked
compressor.Toggle switch, temperature controller com. indicator and indicating lamps are located on the instrument for easy
handling and visibility. Complete with automatic internal light, connecting card & plug to work on 220 volts A/C.
|
|
Inner Chamber Size
610 x 455 x 410 mm (4.0 C.ft.)
830 x 505 x 415 mm (6.0 C. ft.)
875 x 570 x 550 mm (10 C. ft.)
950 x 650 x 550 mm (12 C. ft.)
950 x 700 x 650 mm (15 C. ft.)
|
|
| |
|
|
|
| |
| |
|
|
 |
Laboratory Autoclave (Vertical) Dr 123 |
 |
|
|
 |
|
It is used for
sterilization under saturated pressure at any selected point between 10 to 20 p.s.i. (adjustable). These are double walled
units with inner chamber (Boiler) made of 18 S.W.G. stainless steel and outer chamber is covered with S.S.Lid is tightened
by wing nuts/radial locking system (AS ORDERED). Fitted with neoprene rubber gasket, all system are hydraulically tested
upto 40 p.s.i. as a safety measure. All autoclaves are fitted with standard accessories such as water indicator, pressure
gauge, steam release cock, spring loaded safety valve and heating element. Supplied complete with S.S basket, cord and plug
to work on 220/230 volts A.C. supply.
|
|
All these Models besides being fitted with Stainless Steel/Gunmetal Ltd.
and having inner chamber made of S.S. and outer chamber covered with stainless steel, are also fitted with
|
VACCUM BREAKER as a SAFETY DEVICE. As per the sizes.
Ht. x Dia. Inside Outer M.S. Outer S.S.
18” x
10” (450 x 250 mm)
20” x 12” (500 x 300 mm)
22” x 14” (550 x 350 mm)
24''x
18" (600 x 400 mm)
24” x 18” (600 x 450 mm)
30” x 22” (750 x 550 mm) |
|
| |
|
|
|
| |
| |
|
|
 |
Vaccum Oven |
 |
|
|
![]() |
|
These are double walled units with outer made of M.S. sheet duly enamel painted and
inner made up of heavy gauge S. S. sheet. Gaps between the two walls is dully fitted with high grade glass wood to avoid
thermal loss. Temperature range from 50º C to 150º C is controlled by hydraulic type thermostat with an accuracy of ± 1º C
It is capable of withstanding a high vacuum. Provided with vacuum gauge, see through transparent window of toughened glass
and one shelf. To work on 220/230 Volts A.C. Supply.
|
|
Inner Chamber Size
- 250 x 250 mm
- 250 x 300 mm
- 300 x 300 mm
|
|
| |
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
 |
Heating Mantle |
 |
|
|
 |
|
Heating Mantles (Made of Glass Yarn) with ON/OFF Switch
It withstands high temperature up to 350 Deg C. The body of the mantle is spun
one piece from no rusting Aluminum (unto 5.0 Liters capacity) duly stoving
painted. All heating mantles are lagged with special grade mineral wool.
To work 220/230 volts.A.C.
|
|
Sr.No.
|
Flask Cap.
|
Rating Watt
|
|
A.
|
50 / 100 ml
|
60
|
|
B.
|
250 ml
|
150
|
|
C.
|
500 ml
|
200
|
|
D.
|
1000 ml
|
300
|
|
E.
|
2000 ml
|
450
|
|
F.
|
3000 ml
|
500
|
|
G.
|
5000 ml
|
600
|
|
H.
|
10 Liters
|
2 x 500
|
|
| Note ; Please asked me for other size requirement |
|
| |
|
|
|
| |
| |
|
|
 |
SLIDE WARMING TABLE DR-223 |
 |
|
|
 |
A versatile equipment to heat slides with just microtomed sections to attain maximum flatness before taining. Temperature range ambient temperature is thermostatically controlled. The body is made out of thick mild steel duly finished in stoving enamel and top is made of highly polished copper or stainless steel sheet. Complete with thermostatic control knob, indicator lamp, plug & cord etc. to work on 220 V AC 50 Hz single phase.
Available Sizes
a) 30x25cm (12”x10”)
b) 40x25cm (16”x10”)
c) 45x30cm (18”x12”)
d) 60x15cm (24”x6”)
|
| |
|
|
|
| |
| |
|
|
 |
Oven and Incubator Combined |
 |
|
|
 |
|
| |
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
 |
Humidity Cabinet (Refrigrated type) |
 |
|
|
 |
|
| |
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
 |
Environmental Test Chamber |
 |
|
|
 |
|
| |
|
|
|
| |
| |
|
|
|
|
| |
| |
|
|
 |
High Pressure Horizontal Sterlizer |
 |
|
|
 |
|
| |
|
|
|
| |
| |
|
|
 |
OIL BATH (High temperature) DR-142 |
 |
|
|
 |
Double wall construction. Inner chamber made of highly polished stainless steel or copper sheet and outer made of mild steel duly finished in stoving enamel. Temperature range 50oC to 250oC + 2oC is controlled by a thermostat. Supplied complete with stirrer, diffuser shelves, cover etc. panel provided with on-off switch, pilot lamps thermostatic control knob etc.
Chamber Size in mm & Inches approx.
a. 250x250x250 (10”x10”x10”)
b. 300x300x250 (12”x12”x10”)
c. 350x 350x250 (14”x14”x10”)
Optional :-
i) Mercury contact thermometer and relay with accuracy better than 1°C.
ii) Imported thermostat ‘EGO”/”JUMO’ german with accuracy of 1°C.
iii) Digital temp. Indicator- Cum- Controller.
iv) Microprocessor PID Digital temp. Indicator- cum- Controller .
v) Digital temp. Indicator.
|
| |
|
|
|
| |
| |
|
|
 |
WATER BATH PARAFFIN DR-138 |
 |
|
|
 |
Temp. controlled by mercury contact thermometer with a sensitivity of 0.2oC.Suitable for precision laboratory activities requiring constant temp. with high degree of accuracy. Complete with stirrer with speed control regulator workable on 220V AC 50 Hz single phase but provided with cups & sleeves for glass tubes.
a. 4 Cups & 6 Sleeves.
b. 6 Cups & 8 Sleeves.
c. 12 Cups & 14 Sleeves.
|
| |
|
|
|
| |
| |
|
|